• ASNI/HPVA Type I Water Resistance : Wood glues

    Type I testing involves cutting the 6" by 6" assemblies into 1" by 3" specimens, boiling them for 4 hours, then baking the specimens in a 145°F oven for 20 hours. They are boiled for an additional 4 hours, then immediately cooled using running water. The specimens are sheared while wet, and the bonds must pass certain strength and wood failure requirements to pass the Type I specification.

These products are compliant with this specification: